Revotron Engineering manufacture & supply wide range of venturi tubes with various material of construction.
TECHNICAL SPECIFICATIONS
Specifications | Details |
Applications : | Oil & Gas / Petrochemical Industries / Power Stations |
Type and Construction : | Manufactured by bar stock / Manufactured by welded plate / For big size and very high wall thickness Venturi Meter can also be manufactured by forging / Conical divergent angle of 7 Deg for low loss venturi / conical divergent angle of 15 Degd for Classical Venturi / All types can be supplied truncated or not truncated / Process connections: all types / Instrument connections: all types / Venturi tube for rectangular duct Pressure Taps: With annular chamber (for classic/standard applications) / With piezometric ring (for light applications) / direct pressure taps (for high wall thickness and heavy applications) |
Material : | All material requested by the customer / Material Specifications: all /Main material Reference: ASTM-ASME Code |
Flow Calculation : | Main Reference code: ISO 5167 ASME MFC-3M / Other standards: ANSI 2630 /AGA-3/A PI.Ch.14 (1992)/Miller-Spinks-Shell Engineering Handbook |
STANDARD LIMITS AND APPLICATION FIELDS
Specifications | Details |
Dimensions : | Venturi by bar stock: 2 Inch to 10 Inch / Venturi by welded plate: up to 48 Inch (and above, where acceptable by the Customer) / Venturi by forging: all dimensions |
Beta Ratio : | Venturi by bar stock: 0.4 to 0.75 / Venturi by welded plate: 0.4 to 0.7 / Venturi By Forging: 0.3 to 0.75 |
Reynolds Number Range : | Venturi by bar stock: 200000 to 1000000 / Venturi by welded plate 200000 to 200000 Venturi by forging: 200000 to 2000000. |
PERFORMANCES
Specifications | Details |
Accuracy (referred to flow coefficient): | As per ISO Code |
Rangeability : | 1 to 3 |
Repeatability : | +/- 0.1% |
Max PPL : | (5-15) % of full scale differential pressure |
Straight Lengths Requirements : | As Specified In ISO 5167 International Code |
CALIBRATION
Accuracy (referred to flow coefficient) after calibration in accredited lab: (+/- 0.5%).
NOTE
1. Flow Meters can be manufactured according to all client specifications
2. Flow Meter can be supplied with all suitable accessories (valves / manifold / condensing pot / transmitter / fitting / tubing).