Revotron Pressure Reductions are designed to reduce the fluid pressure. The table here below summarizes typical applications and calculation criteria.
TECHNICAL SPECIFICATIONS
Specifications | Details |
Applications : | Oil & Gas / Petrochemical Industries / Power Stations |
Type Of Elements : | Single Stage Restriction (refer to pipe taps configuration in-ISO 5167 and in Miller Engineering Handbook) Critical Restriction (typically sized according to Miller Engineering Handbook) Multistage Restriction (sized according to standard calculation). |
Material : | All material requested by the customer / Material Specifications: all Main Material Reference: ASTM- ASME Code |
Type of Multistage Construction : | With body by bar stock / With body from pipe |
Calculation : | Accuracy (referred to the pressure drop): +/- 2% up to 1 1/2 Inch; +/- 1% for 2 Inch and above) Gas Service: multistage calculation is performed to avoid to have sound velocity in the vena contracta section of each stage. Liquid Service: multistage calculation shall be carried out to avoid cavitation. |